Fabricated Spring Loaded RTD (Pt100/Pt1000) Inserts

Product Code: PSL

The PSL spring loaded RTD inserts are designed to suit new or existing heavy duty thermowells. Most commonly supplied with a 6.0mm outside probe diameter (3.0mm, 4.5mm and 8.0mm also available).

A ceramic terminal block is supplied as standard and can be connected to a terminal head using the spring loaded screws. An optional 4~20mA transmitter can be supplied instead of the ceramic terminal block, if required.

Spring loading ensures that the sensor tip is kept in contact with the tip of the thermowell, which promotes a faster and more reliable response.

The PSL sensor is supplied with a rigid 316 Stainless Steel sheath. Where the design allows, the sensors are powder-filled to protect the element from damage caused by vibration.

Suitable for use between -75°C and +260°C.

  • Features
  • Options
  • Documents
  • Software
    • Pt100 or Pt1000 as standard (other elements available)
    • 3.0mm, 4.5mm, 6.0mm, 8.0mm Øprobe
    • Fast, reliable response due to spring loading
    • Suits new or existing heavy duty thermowells
    • Suitable for use between -75°C and +260°C
  • Item Code
    Sensor Type Fabricated Spring Loaded RTD (Pt100) Insert PSL
    Fabricated Spring Loaded RTD (Pt1000) Insert PSLK

    Probe Diameter (D1)

    (316 Stainless Steel)

    3.0mm 3.0
    4.5mm  4.5
    6.0mm 6.0
    8.0mm 8.0
    Detector Elements Simplex (1 channel) S
    Duplex (2 channels) D
    Probe Length (mm) (L1) As required to suit your application e.g. 250
    Wiring Configuration 2-wire 2
    3-wire 3
    4-wire (Simplex only) 4
    Grade of Element B (Accuracy: ±0.30°C at 0°C, ±0.80°C at 100°C) B
    A (Accuracy: ±0.15°C at 0°C, ±0.35°C at 100°C) A
    1/3 (Accuracy: ±0.08°C at 0°C, ±0.19°C at 100°C) 1/3
    1/5 (Accuracy: ±0.05°C at 0°C, ±0.15°C at 100°C) 1/5
    1/10 (Accuracy: ±0.03°C at 0°C, ±0.12°C at 100°C) 1/10
    Optional Head Mounting 4~20mA Transmitter

    Linearised, head mounting 4~20mA transmitter, 24VDC power supply, non-isolated. Replaces ceramic terminal block (pre-ranged to suit your requirements).

    ATEX versions also available.

    TXHU (range)

    e.g.

    TXHU (0/200°C)

     

    Order Code (example): PSL-6.0-S-250-3-B-TXHU (0/200°C)

  • No software available