FEMA Rod Thermostat
Product Code: TX
Without Immersion Tube
Rod thermostats can be installed as immersion thermostats in pipelines and containers and for monitoring temperature in air ducts. The thermostats are normally inserted into immersion wells.
For further information regarding immersion wells please contact sales.
- Features
- Technical
- Options
- Documents
- Software
-
- Without immersion tube
- Can be installed as immersion thermostats in pipelines and containers, and for monitoring air duct temperatures
- Various setting ranges
- Protection class IP54
-
Technical Details Housing Material Die cast aluminium GD AI Si 12 to DIN 1725 Mounting Position Any, preferably vertical Electrical Connection Plug DIN EN 175301 Protection Class IP54 according to DIN EN60529 (with vertical installation) Ambient Temperature -15°C to +70°C Switch Function/Capacity SPDT 250 VAC, 8(5) A Contact Arrangement Single pole changeover switch Switching Temperature Adjustable from outside with a screwdriver Switching Differential Not adjustable -
Immersion Length Setting Range Switching Differential (mean values) Max. Permissable Temperature at Sensor Order Code 135mm -20°C to +30°C 1.5 K +110°C TX023 +10°C to +50°C 1.5 K +110°C TX150 +40°C to +90°C 2.5 K +125°C TX490 +80°C to +130°C 4.0 K +150°C TX813 220mm -20°C to +30°C 1.5 K +110°C TXB023 +10°C to +50°C 1.5 K +110°C TXB150 +40°C to +90°C 2.5 K +125°C TXB490 +80°C to +130°C 4.0 K +150°C TXB813 -
No documents available
-
No software available
FEMA immersion wells to suit the above also available. Contact sales for further information.