24V DC Power Supply.
The TXH range of Linearised transmitters can be supplied pre-ranged to suit your application requirements. Alternatively the transmitters can be easily programmed on site by PC using a USB port driven confguration kit. Simply connect two clips to the transmitter and follow the software instructions - specialist calibration equipment is not required! Incorporates the latest digital technology to ensure accurate drift free performance.
- Input Types: Thermocouple Types K, J, N, E, T, R & S.
- Temperature Range: Supplied pre-ranged as ordered or Programmable (confguration kit required).
-
Accuracy:
- Types K, J, E, N: ±0.1% of FS ±0.5°C (plus sensor error)
- Type T: ±0.2% of FS ±0.5°C (plus sensor error)
- Types R, S: ±0.1% of FS ±0.5°C over the range 800 to 1600°C (plus sensor error)
- Isolation: Tested to 250 V dc
- Sensor Burnout: Either Upscale or Downscale (as specifed)
Output
- Output Type: 2 wire 4~20mA current loop
- Maximum Output: 21.5mA (in high burnout condition)
- Minimum Output: 3.8mA (in low burnout condition)
General
- Update Time: 500ms
- Response Time: 1 second (90%)
- Start Up Time: 4 seconds (output < 4mA during start up)
- Warm Up Time: 1 minute to full accuracy
- Power Supply: 10 to 30 Volts dc
Environmental
- Ambient Operating Temperature: -40 to 85°C
- Ambient Humidity Range: 10 to 90% RH non condensing
- Dimensions: 43mm diameter x 21mm high
Also available: Low Cost USB Port Driven Configuration Kit (TX-KIT). Contact sales for further information.
![]() | ![]() |
![]() (TX-KIT) PC USB Configuration Kit | ![]() (TXH) Head-Mounting 4~20mA Thermocouple Transmitter | ![]() (CP) Single Pair Heat Resistant (HR) PVC Flat Twin (105°C) |